跳到正文
arXiv cs.AI· Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran, Ian McLoughlin, Roozbeh Razavi-Far, Hung Cao·· 4 小时前AI 评分18

TriX-EEG:面向可信可解释脑电伪迹去除评估的三级统一框架

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

AI 导读

研究提出 TriX-EEG 三级框架,用于可信且可解释的脑电伪迹去除评估,弥补仅靠重建指标无法判断伪迹抑制与神经活动保留的缺陷。该框架包含信号有效性、去除忠实性与解释可靠性三个层级,在 EEGDenoiseNet 和 PhysioNet 运动伪迹数据集衍生的三个公开基准上评测了九种已发表神经降噪器,覆盖 EOG、EMG 与运动伪迹。

正文 · 原文

View PDF HTML (experimental)

Abstract:Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.
Comments: IEEE journal manuscript under review
Subjects: Signal Processing (eess.SP); Artificial Intelligence (cs.AI)
Cite as: arXiv:2611.21781 [eess.SP]
  (or arXiv:2611.21781v1 [eess.SP] for this version)
  https://doi.org/10.48550/arXiv.2611.21781

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Phat Lam [view email]
[v1] Mon, 16 Nov 2026 19:06:53 UTC (2,013 KB)

来源:arXiv cs.AI · arxiv.org