arXiv cs.CL· Sebastian Wind, Tri-Thien Nguyen, Jeta Sopa, Mahshad Lotfinia, Sebastian Bickelhaup, Michael Uder, Harald K\"ostler, Gerhard Wellein, Sven Nebelung, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh·· 11 小时前AI 评分58
临床 LLM 的安全性与准确率在不同部署条件下出现分化
Safety and accuracy diverge across deployment conditions in clinical large language models
AI 导读
研究提出 SaFE-Scale 评测框架,并在 RadSaFE-200 上评估 34 个本地 LLM,覆盖闭卷、证据支撑、标准与智能体 RAG、最大上下文提示等六种部署条件。
正文 · 原文
Authors:Sebastian Wind, Tri-Thien Nguyen, Jeta Sopa, Mahshad Lotfinia, Sebastian Bickelhaup, Michael Uder, Harald Köstler, Gerhard Wellein, Sven Nebelung, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
Abstract:Clinical large language models (LLMs) are commonly scaled by increasing model size, context length, retrieval complexity, or inference-time compute, on the assumption that higher accuracy implies safer behavior. In medicine, where a few confident or evidence-contradicting errors can outweigh average performance, this assumption may be incomplete. We introduce Safety-Focused Evaluation of Scaling (SaFE-Scale) and instantiate it on RadSaFE-200, a 200-question text-based radiology multiple-choice benchmark with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. Thirty-four local LLMs were evaluated across six deployment conditions spanning closed-book, evidence-grounded, standard and agentic retrieval- augmented generation (RAG), and max-context prompting. Clean clinician-written evidence, used as an upper-bound, produced the strongest joint gain, raising mean accuracy from 73.5% to 94.1% and reducing high-risk error from 12.0% to 2.6% and dangerous overconfidence from 8.0% to 1.6%. Standard and agentic RAG, max-context prompting, and inference-time compute improved selected metrics but did not reproduce this safety profile. Clinically, consequential errors concentrated in a small subset of questions, and variance decomposition placed deployment condition above model family on every safety metric. Within this evaluation, clinical LLM safety did not track accuracy scaling but emerged as a deployment-level property.
| Comments: | Accepted at npj Digital Medicine |
| Subjects: | Computation and Language (cs.CL); Artificial Intelligence (cs.AI); Machine Learning (cs.LG) |
| Cite as: | arXiv:2605.04039 [cs.CL] |
| (or arXiv:2605.04039v2 [cs.CL] for this version) | |
| https://doi.org/10.48550/arXiv.2605.04039 arXiv-issued DOI via DataCite |
|
| Related DOI: | https://doi.org/10.1038/s41746-026-03455-y
DOI(s) linking to related resources |
Submission history
From: Soroosh Tayebi Arasteh [view email]
[v1]
Tue, 5 May 2026 17:57:19 UTC (567 KB)
[v2]
Thu, 5 Nov 2026 19:25:12 UTC (499 KB)
来源:arXiv cs.CL · arxiv.org